UKAEA-CCFE-PR(23)1612023
Severe plasma transients such as disruptions will impose high magnitude, short duration thermal loads on the plasma-facing first wall of the EU’s DEMOnstration tokamak. Repeated over DEMO’s lifetime, these transients may cumulatively alter the microstructure of first wall structural materials, degrading their performance. The effects of repeate…
-
UKAEA-CCFE-PR(23)902020
Plasma-wall interactions in a commercial-scale fusion power station may exert high transient thermal loads on plasma-facing surfaces, repeatedly subjecting underlying structural materials to high temperatures for short durations. Specimens of the reduced activation ferritic-martensitic steel Eurofer-97 were continuously aged at constant temperat…
-
CLM P541964
Showing 1 - 3 of 3 UKAEA Paper Results