The radial propagation of type-I ELMs in ASDEX Upgrade has been measured using a number of techniques. The most reliable technique uses a filament probe to measure the time difference between two separated probes and yields a mean radial velocity obtained of ~1.5 kms -1 . The radial velocity calculated using a time of flight technique suffers from …