Showing 1 - 2 of 2 UKAEA Paper Results
2016
CCFE-PR(16)24
J. Beal A. Widdowson K. Heinola A. Baron-Wiechec K.J. Gibson J.P. Coad E. Alves B. Lipschultz A. Kirschner H.G. Esser G.F. Matthews S. Brezinsek JET Contributors
Rotating collectors and quartz microbalances (QMBs) are used in JET to provide time-dependent measurements of erosion and deposition. Rotation of collector discs behind apertures allows recording of the long term evolution of deposition. QMBs measure mass change via the frequency deviations of vibrating quartz crystals. These diagnostics are used t…
Preprint Published2015
CCFE-PR(15)19
J. Beal A. Widdowson K. Heinola A. Baron-Wiechec K. J. Gibson J. P. Coad E. Alves B. Lipschultz A. Kirschner G. F. Matthews S. Brezinsek JET-EFDA Contributors
Rotating collectors are used in JET to provide time-resolved measurements of erosion and redeposition of vessel materials. The silicon collecting disks rotate behind an aperture, driven by pulsing of the toroidal magnetic field, with the deposits analysed ex-situ by Nuclear Reaction Analysis. The angular dependence of deposition is mapped to discha…
Preprint Published