2003
A family of Johann configuration curved crystal spectrometers has been designed to share the basic engineering features of compactness, modularity, facility of alignment and focus, and incorporation of solid-state charge coupled device detector arrays. These detectors have intrinsically low noise, useful energy resolution, two-dimensional position …
-
2002
We present a comparison of measured and theoretically modeled Lyman- a intensity ratios of hydrogenlike Al XIII impurity ions in a deuterium base plasma in the COMPASS-D tokamak. The time evolution of the intensity ratios is computed from a collisional-radiative model using measured plasma parameters and compared with line-of-sight integral values …
-
2001
The equilibrium state in tokamak core plasmas has been studied using the relative intensities of resonance x-ray lines. A full spatial analysis involves comparison of the line intensities with ion diffusion calculations, including relevant atomic rates. A zero-dimensional model using a global ion loss rate approximation has also been demonstrated b…
-
1999
An empirical procedure, ‘‘LINT,’’ for relating emission line intensities of intrinsic impurity ions to their elemental contributions to the total, bolometric, radiation loss and the volume-averaged effective ion charge, Zeff , has been developed and applied to limiter plasmas in the JET tokamak. In this article we discuss extensions to the …
-
1996
Crystal and synthetic multilayer diffractors, deployed either as flat Bragg reflectors, or curved, as in the Johann configuration, are used to study the spectrum of COMPASS-D and other tokamaks in the wavelength region of 1–100 A. In this article, we concentrate on the measurement of absolute photon fluxes and the derivation of volume emissivitie…
-
1994
Quantitative measurements of the line and continua emissivities and the analyses of spectral line profiles are essential steps in the interpretation of the x-ray emission from high-temperature fusion plasmas. One method of placing the emissivities on an absolute basis is to use an absolutely calibrated spectrometer to record the data. The overall s…
-
1992
This spectrometer was designed to give access to a wide range of Bragg angles and crystal focal lengths while using the Rowland circle radius as a free parameter. Stability is achieved using a rigid beam or “Rowland chord,” which provides a reference axis for all the critical alignments, the chord length being variable between about 0.2 and 5 m…