1996
Fast charge-coupled device (CCD) detector arrays placed at the output of visible spectrometers are used for multichord Doppler shift analyses on the COMPASS-D and START tokamaks. Unequal magnification in the horizontal and vertical axes allows for optimal matching of throughput and spectral resolution at the CCD detector. This involves cylindrical …
-
1994
A multianode photomultiplier (8X8 anodes of 2.5X2.5 mm2) is used to detect a collection of spectra in a high dispersion echelle spectrometer. A cylindrical lens is placed at the output slit to increase the dispersion at the photomultiplier. The cross talk between adjacent spectra is non-negligible (although
-
1994
Quantitative measurements of the line and continua emissivities and the analyses of spectral line profiles are essential steps in the interpretation of the x-ray emission from high-temperature fusion plasmas. One method of placing the emissivities on an absolute basis is to use an absolutely calibrated spectrometer to record the data. The overall s…
-
1993
Low-aspect-ratio tokamaks offer both the economic advantage of smaller size and a number of physics advantages which are not available at conventional aspect ratio. The Small Tight Aspect Ratio Tokamak (START) [Fusion Technology 1990, edited by B. E. Keen, M. Huguet, and R. Hemsworth (North-Holland, Amsterdam, 1991), Vol. 1, p. 353] was conceived a…
-
1992
The superior etendu available from a Fabry-Perot spectrometer is also accessible when used in reflective mode in producing a narrow bandwidth rejection, or “notch,” filter. We consider the instrumental defects and the practical effects involved in realizing a useful device. A simple figure of merit is obtained which allows the Fabry-Perot chara…
-
1992
This spectrometer was designed to give access to a wide range of Bragg angles and crystal focal lengths while using the Rowland circle radius as a free parameter. Stability is achieved using a rigid beam or “Rowland chord,” which provides a reference axis for all the critical alignments, the chord length being variable between about 0.2 and 5 m…
-
1992
Laser-induced fluorescence (LIF) is a well established technique used to determine the neutral hydrogen density in fusion plasmas.There is a requirement to extend these measurements to the Divertor section of large plasma devices, but this is problematical due to the high levels of stray laser light and background plasma emission. Here we describe …
-
1991
The question of the influence of nonaxisymmetric field perturbations on tokamaks is investigated. Recent experiments in the COMPASS-C tokamak [in Proceedings of the 15th Symposium on Fusion Technology, Utrecht (North-Holland, Amsterdam, 1989), Vol. 1, p. 3611 with externally applied helical fields reveal that magnetic islands do not appear until th…
Showing 61 - 68 of 68 UKAEA Paper Results