Whilst there is a clear scientific and technological need for the technical capabilities of transmission electron microscopes with in-situ ion irradiation, it also requires a collaborative community of international researchers to support such facilities in successfully meeting this demand. Instruments of this type serve to provide fundamental unde…
Implantation of 10 keV helium in 316L steel thin foils was performed in JANNuS-Orsay facility and modelled using a multiscale approach. Density Functional Theory (DFT) atomistic calculations [1] were used to obtain the properties of He and He-vacancy clusters, and the Binary Collision Approximation based code Marlowe was applied to determine the da…