2014
This paper presents two different conceptual designs of neutron cameras for Mega Ampere Spherical Tokamak (MAST) Upgrade. The first one consists of two horizontal cameras, one equatorial and one vertically down-shifted by 65 cm. The second design, viewing the plasma in a poloidal section, also consists of two cameras, one radial and the other one w…
-
2014
The Mega Ampere Spherical Tokamak Upgrade (MAST Upgrade) is intended as a demonstration of the physics viability of the Spherical Tokamak (ST) concept and as a platform for contributing to ITER/DEMO physics. Concerning physics exploitation, MAST Upgrade plasma scenarios can contribute to the ITER Tokamak physics particularly in the field of fast pa…
-
2013
Previous experiments on MAST and other tokamaks have indicated that the level of fast ion redistribution can exceed that expected from classical diffusion and that this level increases with beam power. In this paper we present a quantification of this effect in MAST plasmas using a recently commissioned scanning neutron camera. The observed fast io…
-
2012
A neutron camera with liquid scintillator detectors is used in MAST to measure the neutron emissivity from D (d,n)3He reactions along collimated lines of sight. In this work, the measured recoil proton pulse height spectra generated in the detectors by the incident neutrons is modelled taking into account the energy spectrum of the generated neutro…
-
2010
A prototype neutron camera has been developed and installed at MAST as part of a feasibility study for a multichord neutron camera system with the aim to measure the spatial and time resolved 2.45 MeV neutron emissivity profile. Liquid scintillators coupled to a fast digitizer are used for neutron/ gamma ray digital pulse shape discrimination. The …
Showing 1 - 5 of 5 UKAEA Paper Results