Showing 1 - 3 of 3 UKAEA Paper Results
2004
M. J. Nelson R. Barnsley F. Keenan H. Meyer C. A. Bunting P. G. Carolan N. J. Conway G. Cunningham I. Lehane M. R. Tournianski
A curved crystal spectrometer in Johann configuration has been implemented on MAST to obtain values for electron temperature, ion temperature and toroidal velocity. The spectrometer is used to examine medium Z impurities in the soft x-ray region by utilising a Silicon ( 111 ) crystal, bent using a 4 pin bending jig, and a CCD detector sD t =8 ms d …
Published