1999
A 20-chord Doppler spectrometer is used on the START spherical tokamak to record charge-exchange recombination (CXR) spectra. ‘‘Passive’’ radiation, mostly from near the plasma edge, is also present, and comes from electron-impact excitation of C5+ as well as C6+ CXR due to thermal neutrals. The relatively wide neutral beam, together with t…
-
1999
-
1999
The polarimeter system for ITER features 10 viewing chords covering almost the full poloidal cross section of the plasma in a fan-like arrangement. The 10 laser beams all enter the plasma via 150 mm diam penetrations through the diagnostic plug at the low-field side. Small retroreflectors at the high-field side mirror the laser beams back towards t…
-
1999
-
1998
-
1998
The Small Tight Aspect Ratio Tokamak (START) [A. Sykes et al., Nucl. Fusion 32, 769 (1994)] spherical tokamak has recently achieved the record value of toroidal beta~30% in a tokamak-like configuration. The improvements that have made these results possible are presented along with a description of the global equilibrium parameters of the discharge…
-
1997
A multifrequency pulse radar reflectometer (PRR) has been designed, commissioned, and is operating successfully on the small tight aspect ratio tokamak (START). The data obtained with this technique allow the study of the density profile evolution during the shot, revealing aspects of the plasma behavior during such events as the internal reconnect…
-
1997
The world’s first high-power auxiliary heating experiments in a tight aspect ratio (or spherical) tokamak have been performed on the Small Tight Aspect Ratio Tokomak (START) device [Sykes et al. , Nucl. Fusion 32 , 694 (1992)] at Culham Laboratory, using the 40 keV, 0.5 MW Neutral Beam Injector loaned by the Oak Ridge National Laboratory. Injecti…
-
1996
Fast charge-coupled device (CCD) detector arrays placed at the output of visible spectrometers are used for multichord Doppler shift analyses on the COMPASS-D and START tokamaks. Unequal magnification in the horizontal and vertical axes allows for optimal matching of throughput and spectral resolution at the CCD detector. This involves cylindrical …
-
1995
Electron cyclotron emission (ECE) is a standard diagnostic in present day tokamak devices for temperature measurement. When the plasma density is high enough the emission at some frequencies is cut off. Of these cutoff frequencies, the first frequency to cut off depends on the shape of the density profile. If the density profile can be described by…
Showing 31 - 40 of 43 UKAEA Paper Results