2008
A multichord motional Stark effect MSE system has recently been built on the MAST tokamak. In MAST the π and σ lines of the MSE spectrum overlap due to the low magnetic field typical for present day spherical tokamaks. Also, the field curvature results in a large change in the pitch angle over the observation volume. The measured polarization ang…
-
2006
A major upgrade to the charge exchange recombination spectroscopy system on MAST has recently been implemented. The new system consists of a high-throughput spectrometer coupled to a total of 224 spatial channels, including toroidal and poloidal views of both neutral heating beams on MAST. Radial resolution is 1 cm, comparable to the ion Larmor rad…
-
2006
Exploiting the motional Stark effect MSE in the low magnetic fields of spherical tokamaks such as MAST is complicated by the Doppler smearing of the relatively closely spaced Stark components. Extensive modeling of MSE spectra and the subsequent polarized fraction 20% of spectrally filtered light and signal to noice ratios have been performed takin…
-
2006
The maximum temperature expected in ITER is in the region of 40 keV and the minimum average density of approximately 310 19 m -3 is also expected. The proven capability, convenience, and port occupancy of the LIDAR Thomson scattering approach, demonstrated on JET, makes it an excellent candidate for ITER. Nonetheless, there are formidable design ch…
-
2006
A new edge Thomson scattering diagnostic has been implemented at MAST to complement an existing high spatial resolution ruby laser system and the high time sampling core Nd:YAG system. The Nd:YAG system comprises of four independently controllable lasers. Scattered light from these lasers is viewed at large scattering angle 153° by a special optic…
-
2004
Both ruby laser ( 300 points ) and NdYAG laser ( 19 points ) Thomson scattering systems are used on MAST. Fast nonlinear optical switching shunts laser beams from the four 50 Hz NdYAG lasers to obtain coaxial plasma illumination. The technique allows for future expandability to many laser systems. The ruby laser system is used in parallel. A broadb…
-
2004
The Mega Amp Spherical Torus ( MAST ) diagnostic needs are strongly influenced by physics goals that often require diagnostic integration and cross-mapping, especially in fine-scale investigations, such as transport barriers. Conversely, the unrivalled viewing access to the edge, scrape-off layer ( SOL ) and divertor regions, provided by the MAST o…
-
2004
A curved crystal spectrometer in Johann configuration has been implemented on MAST to obtain values for electron temperature, ion temperature and toroidal velocity. The spectrometer is used to examine medium Z impurities in the soft x-ray region by utilising a Silicon ( 111 ) crystal, bent using a 4 pin bending jig, and a CCD detector sD t =8 ms d …
-
2004
Operating a microchannel plate ( MCP ) in saturated mode provides a simple photon and particle counting detector. However, there is a finite recovery time after individual events during which individual microchannels no longer respond, reducing the overall sensitivity. At continuous high flux levels, the corrections from measured to true flux becom…
-
2004
A bremsstrahlung diagnostic has been deployed on the Mega Ampere Spherical Tokamak ( MAST ) , with matrix viewing of the full plasma cross section in a narrow region of the continuum free of spectral lines. An uncooled CCD detector is used to provide 100 Hz 128 3 128 matrix viewing of the plasma emissivity which is spectrally selected using an inte…