CCFE-PR(17)652017
Using high speed imaging of the divertor volume, the region close to the X-point in MAST is shown to be quiescent. This is confirmed by three different analysis techniques and the quiescent X-point region (QXR) spans from the separatrix to the N = 1.02 flux surface. Local reductions to the atomic density and effects associated with the camera vie…
-
CCFE-PR(17)582017
Methods for density control are of critical importance for future long pulse tokamaks. The EMC3-EIRENE code is being used to investigate the applicability of 3D non-axisymmetric fields for density control in standard and advanced divertor configurations in spherical tokamaks. Part of this effort is understanding Scrape Off layer (SOL) transport mec…
-
CCFE-PR(16)812016
Recent improvements in software tools and methodology have allowed us to perform a more comprehensive in-vessel calibration for all mid-infrared camera systems at JET. A comparison of experimental methods to calculate the non-uniformity correction is described as well as the linearity for the different camera systems. Measurements of the temperatur…
-
2014
A new coherence imaging Doppler spectroscopy diagnostic has been deployed on the UK’s Mega Amp Spherical Tokamak for scrape-off-layer and divertor impurity flow measurements. The system has successfully obtained 2D images of C III, C II, and He II line-of-sight flows, in both the lower divertor and main scrape-off-layer. Flow imaging has been obt…