UKAEA-CCFE-CP(19)232019
The Charge eXchange Recombination Spectroscopy diagnostic system on the ITER plasma core (CXRS core) will provide spatially resolved measurements of plasma parameters. The optical front-end is located in upper port 3 and the light of 460 nm to 665 nm is routed to spectrometers housed in the tritium building. This paper describes the layout of the o…
-
UKAEA-CCFE-CP(18)032018
Recent results from MAST address key physics issues for ITER operations and the design of future devices, by advancing our understanding of through analysis of high-resolution data and numerical modelling. Modelling of the interaction between filaments with BOUT++ indicates filaments separated by more than 5x their width move independently, and …
-
CCFE-PR(16)612016
In the last three years, magnetic reconnection research in the MAST spherical tokamak achieved major progress by use of new 32 chord ion Doppler tomography, 130 channel YAG and 300 channel Ruby Thomson scattering diagnostics. In addition to the previously achieved high power plasma heating during merging, detailed full temperature profile measureme…
-
CCFE-PR(16)312016
This paper describes a recent advances in merging/reconnection experiments in MAST, namely tomographic ion Doppler spectroscopy capability from 2013 which solves the problem of the absence of ion temperature profile measurement during the solenoid-less startup. Providing 32 channel line-integrated spectra from 0.25m< rtangential <1.1m are con…
-
CCFE-PR(15)712015
Electron and ion heating characteristics during merging reconnection startup on the MAST spherical tokamak have been revealed in detail using 130 channel YAG- and 300 channel Ruby-Thomson scattering system and a new 32 chord ion Doppler tomography diagnostic. Detailed 2D profile measurements of electron and ion temperature together with electron de…
-
2014
The proton detector (PD) measures 3 MeV proton yield distributions from deuterium-deuterium fusion reactions within the Mega Amp Spherical Tokamak (MAST). The PD’s compact four-channel system of collimated and individually oriented silicon detectors probes different regions of the plasma, detecting protons (with gyro radii large enough to be unco…
-
2014
Using the recently-installed Fast-Ion Deuterium Alpha (FIDA) spectrometer, the effects of low-frequency (20 - 50 kHz) chirping energetic particle modes with toroidal mode number n = 1 on the NBI-driven fast-ion population in MAST plasmas are considered. Results from the FIDA diagnostic are presented and discussed in the light of the present theoret…
-
2012
-
2011
-
2010
A motional Stark effect MSE diagnostic is now installed and operating routinely on the MAST spherical tokamak, with 35 radial channels, spatial resolution of 2.5 cm, and time resolution of 1 ms at angular noise levels of 0.5°. Conventional albeit very narrow interference filters isolate or polarized emission. Avalanche photodiode detectors with di…
Showing 11 - 20 of 45 UKAEA Paper Results